ShootFlow is a free, open-source raw workflow: ingest, cull, and a raw developer you can run yourself. Its noise-aware demosaic needs to know how noisy a frame is. When the file carries no noise profile, it reads the noise from the frame itself.
Yesterday a new way of making that read, called mpcws, became the default for Bayer sensors. It passed four tests written down before any file was scored, on 11 camera raws no noise read had been tuned on. One sentence in the notes was still open: "X-Trans has not been tested with either read." Fujifilm's X-Trans sensors use a 6 x 6 colour pattern instead of Bayer's 2 x 2, and the demosaic treats them differently. Today's run tested them.
What was run
The data was two X-Trans raws from darktable's public test folder: a test chart and an X-Trans IV frame. Neither had been used anywhere in the venture before. Each frame was binned 4 x 4 into a clean reference, and noise was drawn on top at four signal-to-noise levels, either evenly or before white balance (the way a camera's noise really falls). The tests were the same four as for Bayer, and were written into the eval file before the sweep ran:
- no average loss, and no cell worse than 0.02 dB;
- no new frame where the result is worse than the plain directional demosaic;
- a mean luma gain of at least 0.02 dB;
- no frame 0.1 dB worse than what ships where an oracle (the true noise model) is not also worse.
Result
On 38 judged rows the new read with X-Trans's own colour ramp gains +0.41 dB luma and +0.12 dB colour on average. It still fails tests 2 and 4. On three rows of the X-Trans IV frame it loses 0.10 to 0.15 dB of colour where the oracle does not. So the rule says no: X-Trans files develop exactly as they did.
Most of the luma gain comes from fixing an under-read. At the two noisier levels the old read sees 0.67 of the true noise on average and mpcws sees 0.82.
The part that points somewhere
The losses were all colour, so one more arm was scored as a reading. It decides nothing. This arm uses the same read with the colour ramp Bayer uses. It passes three of the four tests, with colour now at +0.29 dB and one fewer loser to directional than what ships. It fails the last test on two rows, both from the test chart at the lowest signal-to-noise level. There the new read is within 4% of the old one, so the loss comes from the ramp, not from the read.
Two files, one of them a chart, are enough to close a candidate that fails but not to change a default. The next step is already written down: that Bayer-ramp form, rule committed first, on at least six unseen X-Trans bodies that are not charts.
The rows, the judge's output and how to reproduce it are in eval/xtrans-drawn-mpcws-2026-11-24.md.