One sentence in the DNG spec settled three raw-file opcodes, and left three open

ShootFlow runs MapTable and row and column gains on DNG stored raw values: the spec's integer range for OpcodeList1 decides how.

A DNG file can carry three lists of processing steps, called opcodes. The first, OpcodeList1, runs on the raw values exactly as the sensor stored them, before black level or white balance. ShootFlow, the open-source photo pipeline in this repository, already ran five value-mapping opcodes in the later two lists: a lookup table (MapTable), and one offset or gain per row or column (DeltaPerRow, ScalePerColumn and so on). In the first list it named them and did nothing. The reason was simple. Nobody here knew what unit a stored raw value is in. Is an offset of 0.01 a hundredth of the white level, of 65,535, or of one count?

The answer was in the specification all along, for half of them. Chapter 6 of DNG 1.7.1.0 says values are clipped after every opcode "to the logical range of the image being modified. For OpcodeList1, this range is 0 to 2^32-1 for images with a bit depth greater than 16, otherwise 0 to 2^16-1." So the first list works on integers. That decides three of the five:

  • MapTable: the stored value is the table index. A sensor that stores square-root-companded values, to fit a wide range into fewer bits, writes the expansion table here.
  • ScalePerRow and ScalePerColumn: a gain has no unit, so value x gain, rounded half up and clipped to 0 to 65,535, is the same however you read the value. These fix a readout gain mismatch where it happens, on the raw counts with black level included.

The other three still have no unit: the two per-line offsets and MapPolynomial. The text gives none for stored values, and no camera file here carries them, so they stay named and undone.

What the tests show. A synthetic sensor that stored square-root-companded 16-bit values, developed with the expansion table in OpcodeList1, comes out byte-identical to the clean sensor. Without the table it is over 100 8-bit steps off. Rows and columns darkened by known readout gains come back within 3 16-bit steps of 257. Twelve tests check every value against the formula written out separately, on both engines. Four planted bugs each fail 5 to 14 of them: rounding down, an off-by-one table index, wrapping instead of clipping, and an ignored column step. On a 12 MP frame the table takes 0.07 seconds with numpy and a row gain 0.16 seconds.

What is not known. No camera- or converter-written file with these opcodes in its first list has been tried. Adobe's SDK multiplies in 32-bit floats, so a product that lands right on a half step may round one count differently there. The details are in ventures/photo-editing/eval/list1-table-scale-2026-11-13.md.