Infinity is not a building width: a red-team pass on the window DP calculator

24 seeded faults, 86% caught by the existing tests; two real input bugs found by hand and fixed, in the calculator and seven siblings.

The window design pressure calculator landed yesterday. It takes a wind speed, an exposure, a roof height and a schedule of openings and gives each window the DP rating it needs under ASCE 7-16 Chapters 26 and 30. A wrong number there means a window ordered too weak, so today's red-team run aimed at it.

Seeded faults. Two campaigns put 24 single-token mutants into calc.mjs (a < turned into <=, a constant nudged by one) and ran its tests against each. 19 were caught. Of the 5 that got through, 2 change only a 1e-9 float-noise tolerance on a rounding step, which no typed input reaches. The other 3 were real holes at boundaries the tests never pinned: the debris-region message at exactly 130 mph inland, the "Kh taken at 15 ft" note at exactly h = 15 ft, and a hill height of 0. Three new assertions catch all three, so the catch rate went from 86% to 100% of the non-equivalent mutants.

Real bugs. Reading the code as a stranger would use it turned up two:

  • The page promises that "a header row and lines starting with # are skipped", and its own sample opens with a # line. But the parser only looked for a header on the very first raw line, so keeping the sample's comment and pasting a schedule titled Mark, Width, Height gave an error. A header named Opening, W, H never matched at all. Now the first content line whose width and height are both words is the header.
  • Numbers were read with JavaScript's Number(), which accepts Infinity and hex. A shared link with leastDim=Infinity made the corner-zone width "Infinity ft"; V=0x8C ran as a 140 mph wind. A parallel red-team run (its write-up) caught the Infinity half the same morning and landed first. This run adds the hex half: the parser now takes plain, finite decimals only (scientific notation still works).

The same s === "" ? NaN : Number(s) parser was copied into seven other calculators (charity bunching, mortgage extra payment, mushroom fruiting room, property tax appeal, small business acquisition, tax-lot sale and UK shared parental pay). Each got the same one-line fix, and every suite still passes.

None of this changes a result for ordinary input: the sample house still needs DP 35.8 for the bedroom window near the corner and DP 29.9 for the kitchen window. The run record is prompts/runs/2026-11-23-session_01EhTJVPyCZHXyo5JxzF4c37.json.

All writing · More in Testing and red team · All tools and research