A building services IDS often asks one plain question: is every pipe, valve and tank assigned to a system? In IFC4 that answer lives in IfcRelAssignsToGroup, and an IDS asks for it with partOf relation="IFCRELASSIGNSTOGROUP".
IDS Model Check learned to read IFC5 alpha .ifcx files earlier today. That reader built the spatial tree, the property sets, the classifications and the materials. It skipped systems, so an IFC5 model failed that question every time, whatever the file said.
IFC5 writes systems as attributes in a bsi::ifc::system namespace. A pipe says partofsystem: [{ref: <system>}]. A port says connectsto: [{ref: <other port>}] and flowdirection: "SOURCE". A system can say servicesfacility, meaning which building it serves. The reader now turns these into what IFC4X3 uses: IfcRelAssignsToGroup, one IfcRelConnectsPorts per pair of ports, the port's FlowDirection, and IfcRelServicesBuildings. It also stops putting a system into the spatial tree. In STEP a system is assigned to things. It is not contained in a storey.
Checked against the STEP original. Of buildingSMART's 47 public .ifcx examples, one uses systems: Domestic Hot Water, converted from an IFC4X3 file that sits next to it. Both keep the same GlobalIds, so every fact can be compared object by object (eval/ifcx-systems-2026-11-21.md):
| IFC5 read | holds on STEP | |
|---|---|---|
system members (partOf IfcRelAssignsToGroup) | 9 | 9 of 9 |
| port flow directions | 35 | 35 of 35 |
| connected port pairs | 15 | 15 of 15 |
The connection count has a small trap. The STEP file holds 21 IfcRelConnectsPorts, but only 15 distinct pairs, because 6 connections are written in both directions. The IFC5 file writes every connection on both ports. Counted as unordered pairs, they agree exactly. Across all 8 STEP/IFC5 twins, the reader's partOf links now hold on STEP 1,655 times out of 1,657. Nothing else in the comparison moved.
Two gaps are left. The file's servicesfacility points at the building, but the .ifcx has no node for the building, so the reader skips that link and says so. And the ports' predefined type (PIPE) and the system's (WATERSUPPLY) are not in the IFC5 class code, so an IDS that asks for them still fails on .ifcx. One example file is a small sample. The next real test is a system exported by an actual authoring tool.
Try it: drop a .ifcx and an IDS on the checker page. Nothing is uploaded.