A thickness in millimetres is not a plain number: IDS from bSDD now writes measure types

IDS Model Check now types bSDD Real properties as the IFC measure their unit names, with values in SI. 867 of 1,625 such properties get a measure.

IDS Model Check can write an IDS file straight from a class in the buildingSMART Data Dictionary (bSDD): node cli.mjs --from-bsdd CLASS_URI -o spec.ids turns the class's property list into requirements. Until today, it wrote every number the dictionary calls "Real" as IFCREAL. That was wrong, and the fix needed more care than we expected.

Why IFCREAL fails the right models

bSDD types a wall thickness, a compressive strength and a U-value all as "Real". An IFC model stores a thickness as an IfcLengthMeasure, though, and IDS compares a value's IFC type exactly. So a facet typed IFCREAL fails every wall modelled the way IFC intends, and the only value that passes is a bare number.

Writing the measure type is only half the fix. IDS reads a measure in SI units, so a dictionary's "50 to 400 mm" has to become 0.05 to 0.4. We built one small model to check this: three walls in a millimetre project, holding 200 mm and 500 mm as lengths and 200 as a plain number.

IDSwalls that fail
before: IFCREAL, 50 to 400both lengths (wrong type)
type only, bounds left in mmall three
now: IFCLENGTHMEASURE, 0.05 to 0.4the 500 mm wall, and the plain number

IfcTester 0.9.0 gave the same nine verdicts.

Where the units come from

Each bSDD class property lists its units, and often its SI dimension exponents. bSDD's own unit list links 417 of its 616 unit codes to QUDT, which gives each unit a conversion factor, a dimension vector and quantity kinds. We joined the two into a 30 KB table. The dimension vector picks the IFC measure, the factor puts values in SI, and the quantity kind settles cases where two measures share a dimension. A torque and an energy are both kg·m²/s², for example.

Three things went wrong on the way. We found all three by running the generator over bSDD itself.

  1. bSDD's ° links to the wrong unit. It is named "grad (angel degree)", from the German Grad, which means degree. It is linked to QUDT's GRAD, though, and that is the gon: π/200 rad. Read as linked, a 90° angle would be written as 1.414 rad instead of 1.571. The table now reads it as the degree.
  2. QUDT lists several kinds per unit. m³ is a Volume and a SectionModulus, and kPa is a ForcePerArea and a ModulusOfElasticity. A first-match rule turned every volume into a section modulus. A kind now picks the special measure only when the unit names none of the general kinds.
  3. Decibels are ambiguous. QUDT's dB is both a sound power level and a sound pressure level. The first version wrote 254 acoustics properties as power levels, and they are pressure levels. A dB property now stays IFCREAL with a note.

The bSDD link check had the same blind spot. It compared the IDS value 100000 (Pa) with bSDD's 100 (kPa) and warned 18 times. It now compares in SI as well.

What it does on bSDD

We looked at every Real class property outside the IFC dictionary in the answers we cached from bSDD: 1,625 properties in 22 dictionaries.

  • 867 get a measure (18 dictionaries): lengths 243, pressures 165, energies 102 (LCA indicators in MJ), masses 87.
  • 758 stay IFCREAL, and each one says why. 304 have a dimensionless unit (dB, %). 221 have no unit at all. 214 use a unit bSDD's own list doesn't have: LCA impact units such as kg CO2 eq, the word unitless, or W/mK where the list has W/(m·K).
  • 37 properties state a dimension that contradicts their unit. In one acoustics dictionary, the dimension field holds a counter: 1, 2, 3 up to 11 in the length slot of decibel levels. Those properties stay IFCREAL.

We generated IDS files from the same 188 classes with and without the unit table. Facets typed as a measure went from 1 to 454, and the audit and link check results did not change: 39 of 43 files have no audit error (the other 4 repeat their dictionary's own faults), and 43 of 43 have no link error.

What we have not done: check a real project model against a generated file. The evidence so far is one built model, read the same way by two checkers. Percentages stay plain numbers, because an IFC ratio stores 50% as 0.5 and nothing in bSDD says which one a dictionary means.

The full numbers are in the venture's eval/bsdd-units-2026-11-19.md.