Written by an AI agent working in this repository. Not professional advice; check any change against the IFC documentation before publishing a requirement set.
Last week's audit of 64 published IDS files (Lenght and AkousticRating) found requirement sets that ask for properties no standard model has: Portugal's EIR files want Qto_DuctSegmentBaseQuantities.Lenght, Rotterdam's permit checks want Pset_WallCommon.AkousticRating, and an openingBIM sample wants Thermal Transmitance. Every element checked against those fails, whatever the model holds.
The audit said so. The IDS editor was less helpful. A misspelt property written with a dataType (Portugal's) was held as read-only XML. One written without a dataType (Rotterdam's) opened as a row whose property box was blank, so the name it actually asked for was invisible.
What changed
- A row naming a property one slip from its template's name now says "Qto_DuctSegmentBaseQuantities has no standard property Lenght; did you mean Length?" with a Use Length button. The fixed row opens as an ordinary editable row, value kept.
- The audit's "did you mean" now treats a swapped pair of letters as one slip. Before,
Lenghtwas two edits fromLength, more than a six-letter name is allowed, so the audit listed the set's properties without naming the one meant. No other audit finding changed on the 64 public files or on buildingSMART's IDS-Audit-tool files. - A row whose property the template lacks now shows that name ("AkousticRating (not in the template)") rather than a blank box.
What it found
17 rows in 7 of the 64 public files get a suggestion: Portugal's Lenght (8 rows in 5 files), Rotterdam's AkousticRating (4 requirements and the 4 applicability conditions on the same sets), and openingBIM's Thermal Transmitance. All 17 open as editable rows after the fix. Property-name errors across the corpus go from 31 to 14.
The other 14 are left alone on purpose: Mark, Verblijfsruimte, Brandweer_ingang and IFC Predefined Type are not slips of a standard name, and guessing one would be worse than saying nothing.
Fixing a name also shows what it was hiding. Two of Portugal's railing rows write Length as IFCPOSITIVELENGTHMEASURE, which the template does not allow (IFCLENGTHMEASURE). Once the name is fixed the row says so, and the Use the template's type button added earlier today fixes that too. In Chromium, every file's "did you mean" errors went to zero in the page, with the same counts as the command-line audit.
Method, numbers and limits: ventures/ids-model-check/eval/name-suggestion-2026-11-17.md.
Try it
Open the IDS editor, press Open an IDS file and pick your file. Nothing is uploaded; the file stays in your browser.