The sensing-selfcal programme is building a check a robot can run before it trusts a camera calibration it worked out for itself, with no target. Such a check needs an honest error bar on the focal length. The previous step found that error does not fall as 1/n below about 5 views. It guessed that this is also why the leave-one-view-out jackknife had looked far too cautious on 7-view sets. This step tests that guess.
What we did
We wrote four predictions down first. Then we solved target-free bundle adjustment on every subset of 3 to 12 of the 13 views of OpenCV's stereo sample, on both cameras: 16,172 view sets, 10,854 of them new. For each set size we compared three numbers:
- the real spread of the focal length, measured two ways (disjoint pairs of view sets, and every set against the all-view solve);
- the jackknife error bar, from re-solving with each view left out in turn;
- the solver's own σ, from its covariance matrix.
What we found
| views in the set | 4 | 5 | 6 | 8 | 10 |
|---|---|---|---|---|---|
| jackknife / real, left camera | 6.7 | 3.0 | 1.6 | 1.3 | 1.1 |
| jackknife / real, right camera | 6.7 | 4.6 | 1.9 | 1.7 | 1.4 |
| solver σ / real, left camera | 0.17 | 0.23 | 0.23 | 0.24 | 0.24 |
| solver σ / real, right camera | 0.19 | 0.38 | 0.40 | 0.49 | 0.59 |
The guess holds. The jackknife's overstatement falls at every step on both cameras, from 7–8× at 4 views to 1.1–1.4× at 10. Most of the small-set excess comes from a few leave-one-out solves that land near the critical geometry, where focal length is barely observable. The median-based jackknife is "only" 2.4–4.1× at 4 views.
The solver's own σ goes the other way: 2 to 6 times too small at every size. On these unbiased corners it is worse than the 2× we found at the start.
Two of the four predictions failed. The right camera needs about 10 views, not 8, before the jackknife comes within 1.5×. And on that camera the two "real" references disagree by up to 1.7×, so its views do not each add an independent error. That is a modelling assumption a paper has to drop, not lean on.
What it means for a robot
Below about 6 views, neither error bar is usable: the solver's is far too small and the jackknife's far too large. With 10 or more logged views the plain jackknife is a usable, mildly cautious error bar, with nothing borrowed from a sibling camera. Field robots log many more frames than that, so the practical rule is to calibrate from a bigger window, not to invent a new statistic. The limits are the usual ones: one stereo rig, one board, 13 views shared by every set.
Code, data and every number: experiments/m4f_setsize.