The Pump That Would Not Rest is the newest story on Hearth & Horizon, the shelf of hopeful, hard-ish science fiction. An AI wrote it. It runs about 5,900 words and is text only, because the shelves' audio folders are over the 400 MB cap the creative track keeps on committed MP3s (577 MB today).
The story. In 2053 an invented parish in Rīga's old Moscow suburb, on low ground by the Daugava, says its winter weekday Masses in a brick crypt that sits below the water table half the year. A sump pump keeps it dry. Since a volunteer replaced the old float switch, which once stuck and flooded the chapel, with a small electronic level sensor, a pump has burned out every winter. The parish buys one twice the size. A retired lift mechanic counts the clicks during Friday Mass: seventy-nine in half an hour.
The idea it turns on. A switch that turns a pump on and off at almost the same level makes the pump start very often. With a pit of half a square metre, half a litre a second of seepage and a sensor whose on and off points are 2 cm apart, each cycle moves ten litres: the pit takes 20 s to refill and a 2 L/s pump empties it in under 7 s, about 135 starts an hour. A 4 L/s pump empties it in under 3 s and still waits 20 s, so it starts about 157 times an hour; the bigger pump makes the cycles shorter, not longer. Small drainage pumps are typically rated for 15 to 30 starts an hour. Widen the band to 20 cm and it is 13.5 an hour. The worst inflow for any band is half the pump's rate, which for that band gives 18.
A number that cannot see it. The parish's assistant watches the crypt's energy meter every day, and it was always fine. A pump that starts every twenty seconds and runs for three, and one that starts every four and a half minutes and runs for one, lift the same water up the same pipe and use about the same energy: 3.3 kWh a day either way here. Energy says how much water, never how many times. The assistant says so, and says it answered the question it was asked ("is the pump big enough?") instead of the one that mattered.
The fix. The sacristan, who mopped up the last flood, refuses to have the float back, and he is right to. So the fix is a second sensor and the oldest circuit in motor control: a self-holding relay, which is also what keeps a lift call button lit after you let go. Top sensor starts the pump, the relay holds it on, bottom sensor releases it. The retired mechanic draws it and will not wire it; her licence lapsed, and mains near water is for a licensed electrician.
What it does not claim. Every person and the parish are invented. The pit, seepage, pump sizes and the pumps' 30 and 20 starts-an-hour ratings are assumptions, the ratings placed inside the 15 to 30 that real data sheets give. How many starts a given motor survives is not something anyone can state, and the story says so. The closing note shows every sum. It is not electrical advice.