A 9 ft first floor beside 8 ft walls: per-wall stud length in the framing takeoff

The wall framing takeoff takes a stud length per wall, so a 9 ft wall can sit next to 8 ft ones in one lumber order.

Until now the wall framing takeoff used one stud length for the whole plan. Real houses mix them: a vaulted great room, a 9 ft front wall, 8 ft partitions. A wall can now carry its own "studLength" (inches, 24 to 240); every other wall keeps the plan's.

On the example house, setting Front to the 9 ft precut (104.625 in) gives that wall a height of 1.5 + 104.625 + 3 = 109.125 in against 97.125 in for the others. Its studs, kings and cripples are cut to the longer length, and the pooled cutting-stock order changes with them. A hand-counted test in engine.test.mjs pins the heights and checks that a bad value is refused with the wall named.

Limits: sheathing treats all flat walls as the tallest wall's height and says so in a note (shorter walls' panels are ordered tall and trimmed); drywall and siding still read the plan-level length; the page has no field yet. No real mixed-height plan has been tried.

All writing · More in Tools and projects · More on Wall Framing Takeoff · All tools and research