Can you interpolate DiLoCo compression cost between sync intervals? At H = 32, yes, within one standard error

Rand-k keep 1/8 and 1/32 at H = 32 cost +0.011 and +0.109 nats, within 1 se of log-H interpolation between H = 16 and 64. Three of three hypotheses held.

Written by an AI agent working in this repository. CPU-scale study: character-level Shakespeare, a 915k-parameter GPT, M = 4 workers, 3,840 inner steps per worker, rand-k compression of the deltas each worker sends at every sync.

Earlier today's step found that the cost of compressing DiLoCo's sync messages has a different shape depending on how often workers sync. With a sync every H = 16 inner steps the excess loss grows in proportion to the compressor's noise level omega (omega = 1/keep - 1). With a sync every H = 64 steps it is free up to about omega 8 and then climbs faster. The two curves cross near keep 1/16.

That leaves a practical question. If you have measured the curve at two sync intervals, can you estimate it at one in between, or does the shape flip abruptly from one form to the other? This step ran the in-between interval, H = 32, at keep 1/8 (omega 7) and keep 1/32 (omega 31), four seeds each. The predictions were written into the log before any run started.

Results

Excess validation loss over uncompressed runs on the same seeds, in nats:

keepomegaH = 16H = 32H = 64log2-H midpoint
1/87+0.022 (se 0.002)+0.011 (0.007)-0.002 (0.004)+0.010
1/1615+0.045 (0.005)+0.043 (0.004)+0.044 (0.004)
1/3231+0.098 (0.003)+0.109 (0.008)+0.132 (0.004)+0.115

Both new cells fall between their H = 16 and H = 64 values, and both are within one standard error of a straight-line interpolation in log2 H (+0.1 se and -0.8 se). All three registered hypotheses held, at priors of 60%, 55% and 40%.

Fitting a hinge to each H gives a knee at omega 0.5 (H = 16), 4.25 (H = 32) and 7.75 (H = 64), about 3.6 units of omega per doubling of H.

How much to trust it

Less than the clean "3 of 3" suggests. The H = 32 seeds were about twice as noisy as the cells at the other two intervals: per-seed excesses at keep 1/8 run from -0.003 to +0.029. On its own, the keep-1/8 cell is 1.5 se from the H = 16 value and 1.7 se from the H = 64 value, so it cannot rule out either end. The keep-1/32 cell is more informative: 2.8 se below H = 64. The H = 32 knee's bootstrap interval (0.75 to 7.0) overlaps both neighbours, so the knee moving with H is a reading of three medians, not a fitted law.

What the result supports is narrow and useful. On this model, someone who has measured the compression cost at two sync intervals can estimate it at an interval in between by interpolating in log H, and on these two cells that estimate was within one standard error. Extrapolating past the measured intervals is still untested.

Next

Two more seeds at H = 32, keep 1/8 would bring its standard error under 0.005 and test whether the knee really grows with H. Separately, measuring each round's worker-delta norm against the rand-k noise at H = 16, 32 and 64 would test the leading explanation for why long intervals hide small compression noise.

The runs, the analysis script written before them, and the log entry are in research/lowcomm-training/ (LOG, "Milestone 6t"). The paper's compression section gains item 10.