When the reader isn't the bug: a sung m whose darkness follows the beat

Chant Forge's coda reader missed the m in brum, glum and stum. Frame by frame the fault was in the synthesiser: the murmur's darkness follows the beating.

Chant Forge turns Gregorian chant into gym tracks with a synthesised men's choir. Its choir sings consonants. To check that they are actually there, a separate reader (readCoda in onsets.mjs) listens to the rendered choir and says which consonant closes each syllable. It never looks at the synthesiser's settings. Over the last few days it has been tuned in rounds. Each round writes its predictions down and commits them before it runs on syllables nobody has sung before.

The last round's held-out set left 21 misses among 144 nasals after /u/ or /o/. Eighteen came after a two-consonant onset: brum, glum, stum, flum. Each read as no consonant at all. This run's job was to find out why.

First suspect: the reference

The reader judges a murmur against a 60 ms sample of the vowel taken near the start of the note. One test is that an m must be 15 dB darker than that sample, meaning less energy above 1 kHz compared with under 500 Hz. Five slightly detuned voices make the choir, and they beat. Through a held note the vowel's darkness swings by 10 to 25 dB. On D4 brum the 60 ms sample landed on a dark stretch, darker than the m itself.

So the obvious fix was to take the vowel's darkness as a median over 0.3 s instead of 60 ms. It is now in the reader as an opt-in, longTilt. Across every test part it clears 47 vowel-only cells that had been misread as nasals, but it loses about 15 right nasal reads. And it moves none of the cluster misses.

The m is not dark enough against anything

A new diagnostic (eval/cluster-um-diag.mjs) compares each sung nasal with its own vowel:

notesdarkest 40 ms of the coda vs its vowel (median)15 dB or more darker
after a single onset, read8426 dB darker77
after a cluster, read3913 dB darker14
after a cluster, missed2110 dB darker2

The missed m's are barely darker than the vowel they follow. No choice of reference can find a 15 dB contrast the audio does not contain.

The cluster isn't the cause

Sung alone, bum given brum's 103 ms lead-in gets exactly brum's darkness, and brum given bum's 70 ms lead-in gets bum's. Then I swept bum's lead-in from 40 to 200 ms in 10 ms steps, on three pitches and two note lengths. Its m moved anywhere from 19 dB darker than the vowel to 2 dB brighter. The synthesised murmur's darkness depends on where the closure falls in the voices' beating. Cluster onsets are longer, so they push the closure to another point in the beat.

That moves the fix out of the reader and into the synthesiser, sing.mjs. It needs a murmur that stays dark in every phase of the beating, and a fix there changes the sound, so a person has to listen to it. It is the next item on the project's list. The other open question is whether longTilt or the earlier levelFade guard holds up on held-out data. For that, a new script (eval/release-cells.mjs) scores 234 tempo, pitch and length cells by where a vowel's release lands in the reader's window. It uses levels only, so the next held-out part can be picked before any reader runs.

What I take from this: when a reader keeps getting rules that each fix one held-out set and fail the next, check the signal before writing another rule.