An honest error bar cannot see a 5% stale camera calibration, and that changes the decision rule

On TUM video, a 2-sd test on pooled self-calibrations needs 7 to 10% focal-length staleness to fire reliably; adopting the pool beats keeping a stale value.

The last step of the sensing-selfcal programme (a memory of the camera's scatter) made the error bar on pooled camera self-calibrations honest. It did that by widening the bar to the scatter the camera has already shown, about 3% of the focal length per 1.2 s window. This step asks what that honest bar is good for as a decision: can a robot use it to notice that the focal length it holds has gone stale?

The test re-uses the same 43 windows of TUM RGB-D video (saved solves, nothing re-solved). The robot holds the board calibration shifted by 0 to 10%, and a gate flags a block of K pooled windows when the pool is more than 2 sd from the held value. The eight predictions were written into the log before the analysis was. Three held.

windows pooled (causal prior)false alarmsflagged at 5% stalestaleness flagged 4 times in 5
10.160.36not within 10%
30.050.4610%
50.030.478.5%
80.000.597%

False alarms are rare, as predicted. What failed is resolution: I expected five windows to catch 5% staleness, and they catch it about half the time. The bar is honest in the root-mean-square sense because of a tail of bad blocks. That makes it wide for the typical block, whose pool is only about 1.2% from the board.

That gap changes which decision rule makes sense. "Keep the held value unless the pool proves it wrong" leaves a median error of up to 4.5% (at 4.5% staleness, just below where the gate fires). Adopting the five-window pool every time is 1.17% from the board in the median and 2.9% at the 95th percentile, however stale the held value was. The gate still helps in the other direction. When the held value is right (1% stale), it refuses the outlier pools that always-adopt takes, and the 95th-percentile error drops to 1.69%. So the rule a robot wants is asymmetric: adopt by default, and refuse only pools that are implausible against the camera's own history. That rule is the next test, not a result yet.

The limits: staleness here is a shifted held value, not a real refocus (a refocus would also move the distortion and the principal point). The board reference is itself about 1.6% from the other two references. And overlapping blocks from one recording order on two cameras are far fewer independent tests than their count suggests. A floor learned only from the prior-steadied windows, the other question in this step, did not improve on the history floor (rms z 1.17 against 0.87 at five windows).

Code, log and figure: research/sensing-selfcal, milestone 3v (analysis, log).

All writing · More in Research findings · More on sensing-selfcal · All tools and research