A room is not a storey: floor-by-floor views and a section plane for IFC takeoff

IFC Quantity Takeoff's 3D view now hides storeys and cuts sections. Building the storey list showed a school model's 5 floors as 198.

IFC Quantity Takeoff draws a model in 3D from the same solids its volumes are computed from. Until today it drew the whole building at once, which is fine for a house and no use for a school: you cannot see the ground floor's partitions through four floors of slabs. So the view now has two things every model viewer has, still with no library.

Storeys, one at a time

There is a tick box per storey, listed lowest first with its elevation and how many elements it holds. Untick the ones you don't want. Nothing is re-meshed or re-uploaded: the elements of each storey are runs in one vertex buffer, and the view simply draws fewer runs. If you then click a bill-of-quantities line whose elements are on a hidden floor, that floor comes back on.

A section plane

Pick a plan cut, or a vertical cut across x or y, and drag the slider. The cut happens in the shader, for drawing and for picking, so a click only ever selects something still standing. Solids that are cut show their inside faces in flat grey, which reads much like the poché on a drawn section. A plan cut starts 1.2 m above the bottom of what is shown, about where a floor plan is cut. It uses the elements' boxes, not the storey's stated elevation, because elevations are relative to the building: one public model's floor "0,000" sits at 498.3 m in world coordinates.

What the storey list found

The first storey list for a 56 MB school model (ARK_NUS, one of the public test files in the ThatOpen web-ifc repository) had 198 entries: its five floors and 193 room numbers. The exporter places furniture, fittings and some walls in an IfcSpace, and the takeoff had taken whatever spatial element contained an element as its storey. That was not only a viewer problem: "group the bill of quantities by storey" gave you rooms.

Now an element contained in a room climbs the spatial tree to the IfcBuildingStorey above the room, and keeps the room's name as its space. On seven public models:

ModelStoreys listed beforeAfterElements moved
ARK_NUS school19851,268
kleine_Wohnung15437
FZK-Haus, C20 Institute, HouseZ, IfcOpenHouse, Mini Projectunchanged0

The Uniformat II grouping reads a storey's elevation to tell basement walls from upper ones, so moving 1,268 elements could have recoded them. None moved: what sits in rooms is furniture, fittings and partitions, which that rule leaves alone.

The checks, the browser run and what is left (meshing in a worker, capped cut faces, a straight-down camera for plan cuts) are in eval/storeys-and-sections-2026-11-21.md. The tool is free and runs entirely in your browser; its quantities are not a measured survey or a cost estimate.

All writing · More in Tools and projects · All tools and research