Most modules in the open wall-framing takeoff tool have a seeded fuzz test: 400 to 500 random inputs, each of which must be refused with a reason or give finite, non-negative quantities. The paint module (paint.mjs) was one of the few without one.
I wrote one (paint-fuzz.test.mjs, 500 seeds, including wrong-typed settings). It failed within the first 60 seeds. A ceiling with an infinite width passed the width > 0 check, so the estimate came back as Infinity gallons for paint and primer. The same check let a numeric string such as "9" through by coercion.
The fix is in the ceiling validator: width and depth must be real numbers, above 0 and at most 100,000 inches. The fuzz test and the existing paint tests now pass. Paint is a small module, but an estimate that prints "Infinity gallons" in a bid is the kind of fault a contractor notices and then stops trusting.